| Sign In | Join Free | My benadorassociates.com | 
 | 
Place of Origin : china
Brand Name : XK
Model Number : FN12
Certification : ISO9001 / GB / IEC
Supply Ability : 100 Piece/Pieces per Month
Packaging Details : EXPORTING PACKING
MOQ : 1 Piece/Pieces
Price : Negotiation
Max. Current : 1250A
Max. Voltage : 36kv
Standard : IEC
Rated Current : 630A,1250A
Rated Voltage : 36kv
Mechanical life : 10000
keywords : load break switch with fuse
Port : NINGBO
  
  
 What is a load break switch
 Load break switch
 A load break switch is a disconnect switch that has been designed to provide making or breaking of specified currents.
 This is accomplished by addition of equipment that increases the operating speed of the disconnect switch blade and the addition of some type of equipment to alter the arcing phenomena and allow the safe interruption of the arc resulting when switching load currents.
 SF6 Insulated Load Break Switch for the use in medium voltage switchboards for secondary distribution networks.
 SF6 Insulated Load Break Switch for the use in medium voltage switchboards for secondary distribution networks.
 Disconnect switches can be supplied with equipment to provide a limited load switching capability. Arcing horns, whips, and spring actuators are typical at lower voltages.
 These switches are used to de-energize or energize a circuit that possesses some limited amount of magnetic or capacitive current, such as transformer exciting current or line charging currents.
 An air switch can be modified to include a series interrupter (typically vacuum or SF6) for higher voltage and current interrupting levels.
 These interrupters increase the load break capability of the disconnect switch and can be applied for switching load or fault currents of the associated equipment.
| ltem | Unit | Data | |
| Rated voltage | KV | FN12-12D/630 | FN12-12(R)D/125 | 
| Rated frequency | HZ | 12 | |
| Rated current | A | 50 | |
| 1min power frequency withstand voltage | KV | 42 to ground and phases fracture 48 | |
| Lightning impulse withstand voltage | KV | 75 to ground and phases fracture 85 | |
| Rated thermal stable current | KA | 630 | 100 | 
| Rated dynamic stable current | KA | 50 | |
| Rated switching current(peak) | KA | 50 | 50 | 
| Rated short-circuit current(expected) | KV | 31.5 | |
| Maximum breaking current threshold | HZ | Fuse characteratic curve accorting | |
| Minimum breaking current | A | Fuse characteratic curve accorting | |
| Rated transfer current | KV | 50 | 1.5 | 
| Maximum breaking current | KV | 1.8 | |
| Breaking OFF-load transformer capacity | KV/A | 1250 | |
| Rated cable charging current | A | 10 | |
| Rated active load current breaking times | Times | 10000 | |
| Opening time when striker strikes | S | <0.06 | |
| Earth switch thermal current switch | KA | 20(2S) | |
| Thermal stable current of earth switch | KA | 50 | 50 | 
| Motor operating power supply voltage | V | AC/DC 110/220 | |
| ltem | Unit | Data | |
| FN12-10D/630 | FN12-10(R)D/125 | ||
| The total traveling distance of moving contact | mm | 200+8-2 | |
| Phase center distance (Before energy storage) | mm | 210±15 | |
| Moving contact overtravel distance | mm | 40±2 | |
| Auxiliary contact opening distance | mm | >150 | |
| Opening/Closing time difference among three phase | ms | <3 | |
| Opening speed | m/s | >2.8 | >2.8 | 
| Closing speed | m/s | >3.8 | |
| Distance between metal flexible door and torch | mm | >125 | |
| Fracture distance of earth switch | mm | >150 | |
| Main circuit resistance | Ω | <120 | <300 | 
| Maximum operating torque | NM | >160 | |

 
 

Q1. Can we have our logo or company name to be printed on your products or the package? 
 Yes,you can.Logo and company name can be printed on our products by silk screen printing.You can send us the artwork by email in JPEG or TIFF format.
 Q2. What is lead time?
 Usually 3-15 working days, On-Time delivery
 Q3. Why us?
 All products comply with the requirements of GB national standards, IC, ANSI and other international standards, and the requirements of company's technology standards.
 Q4. How do you make our business long-term and good relationship?
 1. Our high quality and competitive price are the most important factors to maintain long-term and good relation -ship with our customers.
 2. Good service is our basic principle for every customers.
 Q5. Can I have a visit to your factory before the order?
 Sure,welcome to visit our factory. 
|   | 
| Electrical 36kv Load Break Switch With Fuse 10000 Mechanical Long Life Images | 
 12kv Indoor Motorized Load Break Switch / 3 Phase Fused Isolator Switch
                                                                                    
                        
                        
                        
                                                            12kv Indoor Motorized Load Break Switch / 3 Phase Fused Isolator Switch
                                                    
                        
                     Pad Mounted Transformer Load Break Switch / High Voltage Isolator Switch
                                                                                    
                        
                        
                        
                                                            Pad Mounted Transformer Load Break Switch / High Voltage Isolator Switch
                                                    
                        
                     Air Fused Vacuum Load Break Switch / 11 Kv Isolator With Earth Switch
                                                                                    
                        
                        
                        
                                                            Air Fused Vacuum Load Break Switch / 11 Kv Isolator With Earth Switch
                                                    
                        
                     11kv Isolator Switch 3 Phase 630A Max Current 10000 Long Mechanical Life
                                                                                    
                        
                        
                        
                                                            11kv Isolator Switch 3 Phase 630A Max Current 10000 Long Mechanical Life
                                                    
                        
                     Hv Vacuum Load Break Switch Easy Operation 20kv Gang Isolator IEC Standard
                                                                                    
                        
                        
                        
                                                            Hv Vacuum Load Break Switch Easy Operation 20kv Gang Isolator IEC Standard
                                                    
                        
                     12KA Indoor High Voltage Load Disconnect Switch Multi Size Can Be Available
                                                                                    
                        
                        
                        
                                                            12KA Indoor High Voltage Load Disconnect Switch Multi Size Can Be Available
                                                    
                        
                     Vacuum Transformer Fuse Isolator Switch 630A Ma Current IEC Standard
                                                                                    
                        
                        
                        
                                                            Vacuum Transformer Fuse Isolator Switch 630A Ma Current IEC Standard
                                                    
                        
                     12kv 11kv Vacuum Load Break Switch / Electrical Load Break Disconnect
                                                                                    
                        
                        
                        
                                                            12kv 11kv Vacuum Load Break Switch / Electrical Load Break Disconnect
                                                    
                        
                     12kv Electrical 3 Phase Fused Isolator Switch For Extractor Fan High Precision
                                                                                    
                        
                        
                        
                                                            12kv Electrical 3 Phase Fused Isolator Switch For Extractor Fan High Precision
                                                    
                        
                     36kv 11kv Transformer Load Break Switch / Fuse Switch Disconnector Indoor
                                                                                    
                        
                        
                        
                                                            36kv 11kv Transformer Load Break Switch / Fuse Switch Disconnector Indoor